HVAC Guides

Choose a method, understand a result, and plan the next check.

Getting started

Airflow measurement

Duct sizing and geometry

Pressure loss and system checks

Leakage and balancing

Components and terminals

Ventilation and air balance

ACH vs. outdoor-air ventilation rate Distinguish total air changes from outdoor-air ventilation, then choose the calculation that matches the room or dwelling task. Bathroom exhaust airflow and installed duct resistance Calculate an initial intermittent bathroom exhaust target, then check whether the fan can deliver it through the complete installed route. Closed-door return-air pathways and transfer airflow Compare complete parallel return paths using documented pressure-flow curves, a net room-to-hall airflow, and an explicit project pressure limit. CO₂ ventilation estimates: steady state vs. decay Choose a steady-generation balance or a source-free decay model, and interpret the estimated flow only within its measurement assumptions. Commercial hood exhaust and louver selection from matched data Use named product and installation data to screen hood exhaust or louver candidates while preserving unmet pressure, weather, geometry, and code boundaries. Heat-recovery temperature ratio vs. effectiveness Keep a measured supply temperature ratio separate from sensible exchanger effectiveness when the two air streams have different heat-capacity rates. Makeup-air flow balance vs. building pressure Account for simultaneous exhaust and incoming streams, using mass balance when their actual air densities differ. Mixed-air temperature and outdoor-air fraction Choose a temperature-only estimate or a two-state moist-air balance, and keep actual volume fractions separate from dry-air mass fractions. Single-zone vs. multizone outdoor-air calculations Use a single-zone relationship for one zone and a multizone method when central primary flow, concurrent populations, zone efficiencies, and critical-zone effects interact.

Fans and energy

Blade-pass frequency: a frequency check, not a fault diagnosis Calculate blade-event frequencies from blade count and fan shaft RPM, then compare their locations with a compatible measured spectrum without assigning a sound or fault level. Fan balance and vibration criteria: what the readings can establish Keep residual rotor balance, factory vibration, and installed bearing-housing readings separate because their quantities and limits are not interchangeable. Compare fan energy cost across a full operating schedule Compare electrical energy and energy-only charges using average inputs or a complete annual schedule, while keeping shaft power separate from electrical consumption. Fan laws and density: when operating-point comparisons apply Scale a documented fan operating point only when geometry, density, pressure basis, and similarity assumptions match the calculation. Fan power: match pressure basis with efficiency Convert a fan duty point from air power to shaft and electrical power only after matching total or static pressure with the corresponding efficiencies. Fan speed, belt ratios, pulley geometry, and tip speed Calculate the geometric speed relationship and impeller tip speed first, then check the actual belt, motor, fan, vibration, and performance limits. Fan and system curves: operating point and installation effects Find supported intersections between supplied fan and system curves, then keep installation effects separate from ordinary resistance. FEI vs. FEG: what the rating represents Keep Fan Energy Index and Fan Efficiency Grade separate: they use different inputs, boundaries, methods, and evidence.

Thermal and materials

Acoustics